Integrated Skid-Mounted Oil/Gas-Fired Steam Boiler
- Integrated skid-mounted design
All components (boiler body, burner, control cabinet, feedwater system, water treatment system, valves & instruments) are pre-mounted on one base. Pre-assembly and factory pre-commissioning finished before shipment. Clients only need to connect water, electricity and fuel pipelines on site for fast startup, which largely cuts on-site installation time.
- Compact footprint, space-saving layout
Engineers conduct precise calculation to optimize structure. Guaranteed rated output with minimized occupied area, saving workshop space and customer investment cost.
- High thermal efficiency & good steam performance
Ample heating surfaces realize efficient heat absorption, low flue gas temperature and low heat loss. Fast steam generation and superior steam quality with large radiant heating area.
- Fast startup characteristic (LSS series advantage)
Only 20 minutes from cold start to full load. Ideal for working conditions with frequent start-stop demands to supply steam rapidly. Built-in steam-water separator inside drum guarantees high steam dryness.
- Excellent safety performance
Small water volume reduces potential hazard risk compared with conventional boilers. Equipped with complete protection systems: pressure protection, water level protection, overtemperature protection and multiple interlock controls for reliable operation.
Integrated Skid-Mounted Oil/Gas-Fired Steam Boiler
- Integrated skid-mounted design All components (boiler body, burner, control cabinet, feedwater system, water treatment system, valves & instruments) are pre-mounted on one base. Pre-assembly and factory pre-commissioning finished before shipment. Clients only need to connect water, electricity and fuel pipelines on site for fast startup, which largely cuts on-site installation time.
- Compact footprint, space-saving layout Engineers conduct precise calculation to optimize structure. Guaranteed rated output with minimized occupied area, saving workshop space and customer investment cost.
- High thermal efficiency & good steam performance Ample heating surfaces realize efficient heat absorption, low flue gas temperature and low heat loss. Fast steam generation and superior steam quality with large radiant heating area.
- Fast startup characteristic (LSS series advantage) Only 20 minutes from cold start to full load. Ideal for working conditions with frequent start-stop demands to supply steam rapidly. Built-in steam-water separator inside drum guarantees high steam dryness.
- Excellent safety performance Small water volume reduces potential hazard risk compared with conventional boilers. Equipped with complete protection systems: pressure protection, water level protection, overtemperature protection and multiple interlock controls for reliable operation.
| LHS Series Vertical Gas/Oil Fired Steam Boiler Technical Parameters | ||||||||
| Model | Rated Capacity (t/h) | Rated Pressure (MPa) | Steam Temperature (°C) | Max Transport Weight (t) | Max Transport Size (L*W*H) (mm) | Fuel Diesel Consumption (kg/h) | Fuel LPG Consumption (kg/h) | Fuel Gas Consumption (Nm³/h) |
| LHS0.05 | 0.05 | 0.4 | 150 | 0.37 | 700×650×1700 | 8.2 | 6.45 | 10.2 |
| LHS0.1 | 0.1 | 0.59 | 800×750×2000 | 11.3 | 13 | 13.6 | ||
| LHS0.2 | 0.2 | 0.68 | 900×850×2000 | 15.6 | 19.4 | 18.7 | ||
| LHS0.3 | 0.3 | 0.83 | 1000×950×2000 | 22.5 | 25.6 | 26.8 | ||
| LHS0.5 | 0.5 | 0.4~0.7 | 150~170 | 1.07 | 1100×1050×2000 | 32.5 | 32 | 36.8 |
| LHS0.7 | 0.7 | 1.45 | 1200×1150×2200 | 40.6 | 50 | 48.5 | ||
| LHS1 | 1 | 1.78 | 1300×1250×2450 | 45.9 | 65 | 65.3 | ||
| LHS1.5 | 1.5 | 1.9 | 1780×1600×3200 | 78.4 | 97 | 102.1 | ||
| LHS2 | 2 | 5.2 | 2000×2000×4000 | 91.8 | 130 | 130.6 | ||